Land Details:
1. Details of the land is given in the attached drawing.
2. In the drawing you will find a Contour survey or topography of the plot (which differs from actual area on map).
3. In the drawing you will also find a drawing with actual plot details.
4. In the above drawing you will find that area at the back is left as green area, you have to leave this area as green area for the project. Additional green area can be left as per the plan.
5. In the front side you will find that some area is affected under road widening. This area needs to be deducted from the actual area.
6. Area on the map is more than the actual area which is 3890 sq. mtr and after deduction of area under road it is 3569 sq. mtr.
7. 321 sq. mtr of land is coming under road width. we will get double FAR for the this area. this can also be understood from the table shown in the drawing.

Requirements:
1. I need a concept drawing (Autocad) for a residential cum commercial project.
2. The commercial portion may cover the entire ground floor or some part of both ground and first floor.
3. Keep the total commercial area to around 10000 square feet.
4. Commercial area per office/shop should not exceed 400 square feet.
5. Commercial space must have at least one Toilet.
6. No lift is needed in commercial Area.
7. Residential area should comprise of 2 & 3 BHK apartments.
8. 2 BHK with a built up area of around 850 sq ft. and 3 BHK of around 1050 sq. ft.
9. A small club house of around 2000 sq ft. which should have a Gym , table tennis etc.

By Laws:
1. Maximum Ground Coverage should not exceed 30% of the plot area.
2. For a building of height 18m, setback of 6m is to be left all around the building except at the front where the setback should be half of the building height.
3. For a building of height 21m, setback of 7m is to be left all around the building except at the front where the setback should be half of the building height.
4. Floor area ratio allowed is 1.75

Parking Norms:
1. One car parking space for every 125 sq. mtr of Residential Built up area.
2. One car park space for every 75 sq. mtr of Commercial Built up area.
3. Area required for one car park (including circulation space) in :
Basement : 35 [url removed, login to view]
Stilt / Podium : 30 Sq. mtr
Open : 25 [url removed, login to view]
4. Height of Basement / Stilt / Podium parking should not exceed 8 feets

Important Note:

1. Land is around 6 - 9 feet down from the adjoining road. This level difference is to be used for basement parking.
2. 6 mtr clear space is to be kept around the building, space after 6m can be used for open parking.


For any other query.. you can contact me on my email: [url removed, login to view]@[url removed, login to view]

Tavsiye Edilen Beceriler

İşveren Geribildirimi

“Awesome experience.. Great Work,...”

Profil Görüntüsü ankur26384, India.

Genel Açıklama Panosu

  • beehive3dworks
    beehive3dworks
    • 3 yıl önce

    Can u please seal the contest...

    • 3 yıl önce
    1. beehive3dworks
      beehive3dworks
      • 3 yıl önce

      The ground coverage includes builtup area on ground and does not include projections above 2.5 mts... Neither does it include service ducts, lift ducts . So I have not exceeded the ground coverage by 30 % .. Will upload final dwgs soon

      • 3 yıl önce
    2. ankur26384
      Yarışma Sahibi
      • 3 yıl önce

      I am still not sure about it. It wud be great if you can give me a call today itself on my number 9753730000 and explain me so that I can award you the contest.

      • 3 yıl önce
  • arup1971
    arup1971
    • 3 yıl önce

    Ankur you can check my entry no 21 as that has a clearer and improved image.

    • 3 yıl önce
  • beehive3dworks
    beehive3dworks
    • 3 yıl önce

    Hi Ankur, ...Thanks for extending the deadline..I will upload my design entry soon

    • 3 yıl önce
  • arup1971
    arup1971
    • 3 yıl önce

    Hi Ankur... I am again working on this layout design and trying to prepare something spectacular for you. Shall hope to upload by midnight today.

    • 3 yıl önce
  • wrishitesh
    wrishitesh
    • 3 yıl önce

    Hello Ankur, can it be more than one building or it needs to be single? Thanks.

    • 3 yıl önce
    1. wrishitesh
      wrishitesh
      • 3 yıl önce

      Thanks for extending the contest.

      • 3 yıl önce
    2. ankur26384
      Yarışma Sahibi
      • 3 yıl önce

      waiting for your entry

      • 3 yıl önce
  • bernatolentino
    bernatolentino
    • 3 yıl önce

    Thanks for the invitation.

    • 3 yıl önce
  • crystalARCH
    crystalARCH
    • 3 yıl önce

    Thanks for your invitation.

    • 3 yıl önce
  • basitsiddiqui
    basitsiddiqui
    • 3 yıl önce

    Hi Dear, Can you make this contest Guaranteed.

    • 3 yıl önce
    1. rmissin
      rmissin
      • 3 yıl önce

      It tells you right next to the button...

      "Guarantee freelancers that a winner will be chosen and awarded the prize. This will attract better entries from more freelancers. Moneyback guarantee is not applicable if a contest has a guaranteed upgrade."

      • 3 yıl önce
    2. ankur26384
      Yarışma Sahibi
      • 3 yıl önce

      i have made the contest guaranteed.

      • 3 yıl önce
  • arup1971
    arup1971
    • 3 yıl önce

    Hello Ankur
    Let me get this clear before I begin drafting your requirements. You have a site plan drawing but want us to fill in the drawing with Bldg Layouts of blocks as specified by you. All your requirements must be shown in the drawing following the By laws as specified. I guess a new housing complex is going to come up on this plot of land.

    • 3 yıl önce
    1. ankur26384
      Yarışma Sahibi
      • 3 yıl önce

      you are right dear. The only thing u have to keep in mind is the area in the site plan is little more than that on records. So kindly consider the area on record for Ground coverage and FAR calculations.

      • 3 yıl önce
  • wrishitesh
    wrishitesh
    • 3 yıl önce

    Also, what is the max. ht. possible for the plot? plz let me know. Thanks.

    • 3 yıl önce
    1. ankur26384
      Yarışma Sahibi
      • 3 yıl önce

      upto 10 floors.. but i wud like u to end it at 6 floors or a max of 7

      • 3 yıl önce
  • ankit1241993
    ankit1241993
    • 3 yıl önce

    Am I supposed to draw the residential building on the drawing that is to the left of the topography plot?

    • 3 yıl önce
    1. ankur26384
      Yarışma Sahibi
      • 3 yıl önce

      the plot size on that drawing may be more than the actual area i.e. 3890 sq. mtr before deducting the road width.

      • 3 yıl önce
    2. ankur26384
      Yarışma Sahibi
      • 3 yıl önce

      so use 30% ground coverage on (3890 - road width area) i.e. 3569 sq.m. so maximum ground coverage should not exceed 1071 sq.m