
Closed
Posted
Paid on delivery
I need a thorough structural calculation and performance check on a newly designed aluminum profile system, with special focus on the largest 3 m × 3 m configuration before cascading the findings to the smaller variants. The study must cover both static and dynamic load analysis so that I can confirm each profile, connection detail, reinforcement option, and fixing method is truly fit for purpose. Material fatigue is my prime concern, so the calculation package has to explore long-term cyclic effects alongside the usual strength and stiffness checks. If you spot joint failure or deformation risks during the process, flag them, but the fatigue life is the critical pass/fail criterion. Please ground every assumption in recognised codes and clearly document the input data, equations, safety factors, and results. Finite-element modelling, hand verification sheets, and concise summary tables are all welcome as long as they tell a coherent story. Deliverables: • Full calculation report (PDF) with static & dynamic analyses, fatigue assessment, and code references • Editable analysis files (e.g., FEA model, spreadsheets) • A short design-change memo if any modifications are needed to meet the target capacities When you reply, highlight relevant experience with aluminium structures and any similar projects you have taken from concept to verification. Scope of Structural Analysis The consultant/structural engineer shall analyze the newly developed aluminum system considering: Aluminum profile dimensions and geometry Aluminum alloy and mechanical properties Profile thicknesses Profile section properties Span and unsupported lengths Connection and joint details Corner connections Fixing methods Wall/structure attachment methods Internal reinforcement, where applicable Glass/panel loading, where applicable Dead loads Operational loads Wind loads for externally exposed systems Deflection limits Stress and utilization ratios Local buckling and overall stability Connection capacity Load transfer between individual components Structural adequacy of the complete assembled system
Project ID: 40648701
19 proposals
Remote project
Active 2 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
19 freelancers are bidding on average $421 USD for this job

Hi, I reviewed your project requirements and I can help you develop a practical, production-ready solution—not just a visually complete CAD model. I’m a mechanical engineer with 13+ years of experience in product design, mechanical systems, CAD development, engineering analysis, and multidisciplinary coordination. Depending on the project, I can support concept development, detailed 3D modelling, assemblies, manufacturing drawings, BOMs, technical calculations, simulations, and fabrication-ready files. My focus is always on clear drawings, realistic detailing, manufacturability, and fast communication throughout the project. I work mainly with SolidWorks, AutoCAD, ANSYS, Revit, Fusion 360, and related engineering tools. You can review similar design and engineering work in my profile. Once I see the available drawings, dimensions, and expected deliverables, I can suggest the most efficient way to proceed. Best regards, Gökay Zaralı
$650 USD in 7 days
6.5
6.5

Hello, I’m Mohand, a Professional Structural Engineer experienced in aluminum structures, connection design, FEA, and performance verification of engineered systems. **Scope of Work:** 1. Develop the structural analysis model for the critical **3 m × 3 m configuration**, evaluating profile geometry, alloy properties, spans, connections, reinforcement, fixings, panels/glazing, and complete load paths. 2. Perform **static and dynamic analysis**, including dead, operational, wind, stress, deflection, local buckling, stability, connection capacity, and component utilization checks, with hand calculations used to verify key FEA results. 3. Complete a detailed **fatigue assessment** for long-term cyclic loading, document assumptions, code references, safety factors, governing results, and provide design-change recommendations where required. I’ll establish the governing design case from the largest configuration first, then use the verified methodology to assess the smaller variants. I’ll clearly document all assumptions and ensure the final report provides a traceable basis for structural and fatigue performance. Please send the aluminum profile drawings, alloy/temper information, connection details, fixing details, loading requirements, target fatigue cycles, and applicable project location/code requirements so I can begin the assessment. Best Regards, Mohand
$500 USD in 7 days
5.5
5.5

I’m a Structural Engineer with 10+ years of experience, having completed projects for clients in the USA, UK, Canada, Australia, Oman, Saudi Arabia and other countries. I have strong experience in aluminum structures, structural calculations, load analysis and design verification. For your aluminum profile system, I can assess the critical 3 m × 3 m configuration first and cascade the validated results to smaller variants. The study will cover: • Static & dynamic load analysis • Aluminum profile strength, stiffness, buckling and stability • Deflection, stress and utilization checks • Corner joints, fixings, reinforcement and wall attachments • Connection capacity and load transfer • Wind, operational and applicable imposed loads • Long-term cyclic loading and fatigue life as the primary pass/fail criterion • Independent hand calculations to verify FEA results • Code-based assumptions, safety factors and documented calculations I can deliver a professional PDF calculation report, editable FEA/analysis files, spreadsheets and a concise design-change memo where modifications are required. My approach will provide a clear calculation trail from geometry and material data through loading, FEA, hand verification, fatigue assessment and final recommendations. Any profile, connection or fixing risks will be clearly identified. I’m ready to review your drawings, alloy/temper, connection details, loads and applicable design codes.
$500 USD in 7 days
5.7
5.7

I have worked on similar aluminum structural verification projects involving profile systems, façade components, framing assemblies, and FEA-based validation. My experience includes static analysis, fatigue assessment, connection verification, deflection control, and code-based design checks using SolidWorks, ANSYS, and hand calculations. Your emphasis on fatigue performance rather than simple strength verification is exactly the right approach for an aluminum system that will be subjected to repeated loading over its service life. I can start with the critical 3 m × 3 m configuration and develop a complete structural verification package covering profile behavior, connection performance, reinforcements, fixing methods, local buckling, overall stability, and load transfer throughout the assembled system. Analysis approach: 3D FEA model development Static structural analysis Dynamic load assessment Fatigue life evaluation Connection and joint verification Buckling and stability checks Hand-calculation validation Code-based verification and safety factors Deliverables: Complete calculation report (PDF) Static and dynamic analysis results Fatigue assessment report FEA source files Editable calculation spreadsheets Design modification recommendations (if required) Summary tables and engineering documentation Best regards, Bilal
$250 USD in 4 days
3.5
3.5

With a degree in Electrical and Electronics Engineering under my belt, I may not have tackled your precise project of aluminum structural analysis before, but my acute familiarity with comprehensive system analysis proves vital for projects such as yours. One discipline of engineering often echoes into others, and this well-rounded 360-degree knowledge is what I offer. Moreover, my expertise in data science and programming can further enhance the accuracy and efficiency of your project. Parallel to your requirements, where struct Clearance employed and solve electrical challenges.
$500 USD in 7 days
2.5
2.5

Greetings! I can perform a thorough structural calculation and performance check for your aluminum profile system, including static and dynamic analysis, fatigue assessment, and code compliance. I have experience with aluminum structures and similar verification projects. I will deliver a full calculation report, editable analysis files, and a design-change memo if needed. Let me know your preferred timeline and I will begin. Thanks, Revival
$250 USD in 7 days
1.5
1.5

As a seasoned structural engineer with a strong background in CAD and CAE projects, I have successfully completed numerous construction and architectural projects. My expertise extends to finite element analysis - a crucial aspect of your aluminium system's structural validation. I can proficiently use softwares like ANSYS, COMSOL, ABAQUS, NX, and Star Siemens Software to deliver detailed analysis reports that you require. Hand-in-hand with analysis, I am adept at creating precise, streamlined designs using AutoCAD, Solidworks, CATIA, Inventor, and NX. To sum up my pitch: partnering with me means you get access to a round the clock CAD/CAE expert who doesn't spare any effort on efficient problem solving within your budget. I offer customized solutions tailored specifically to your needs. With this collaborative approach in mind, I am excited for the possibility of working with you on this project!
$500 USD in 7 days
1.7
1.7

Hi, I'm a structural engineer (Ph.D. candidate, Structural Engineering) with 7+ years of experience in structural analysis and design — over 300,000 m² of reinforced concrete and steel structures delivered, with strong hands-on FEA modeling (ETABS, SAP2000, IdeaStatica) and dynamic/seismic load analysis background from both practice and university teaching. While my core delivered work has been building structures rather than aluminum profile systems specifically, my analysis methodology directly transfers: rigorous static/dynamic load evaluation, connection capacity checks, deflection/stability verification, and code-referenced documentation are exactly what I apply daily. **My approach for your system:** - Static & dynamic (wind, cyclic) load analysis on the 3m×3m configuration first, cascading to smaller variants - FEA modeling + hand-verification sheets for cross-checking - Fatigue life assessment as the primary pass/fail criterion, alongside stress/utilization, buckling, and joint capacity checks - Design-change memo if targets aren't met **Deliverables:** full calculation report (PDF), editable FEA/spreadsheet files, code references throughout. Support guaranteed until you're fully satisfied. Please check my portfolio on my profile. Best regards, Aleksander Mach
$500 USD in 7 days
0.0
0.0

Hi There!!! i understand you need a full structural calculation and fatigue assessment for your new aluminum profile system, focusing on the largest 3m by 3m configuration before extending results to smaller variants. Working through static and dynamic load analysis, connection details, reinforcement checks and long term cyclic fatigue is the kind of grounded, code referenced engineering work that fits well with a structural review like this. Delivering a full calculation report with clear input data, safety factors and results, alongside editable FEA models or spreadsheets and a short design change memo if needed, matches exactly what you are asking for. Would be great to hop on a quick call to understand the alloy specification, loading conditions and applicable design codes before starting the analysis. Best Regards, Hussain Ahmed Quick questions for you, Which design code or standard should the calculations follow, such as Eurocode or another regional code? Do you have drawings or CAD files ready for the profile geometry and connections? Is this system for interior use or externally exposed, since wind loads will apply differently?
$250 USD in 3 days
0.0
0.0

This project is about ensuring not just compliance but also confidence in your aluminum profile system's performance. The stakes are high when it comes to material fatigue, and I understand that thorough analysis is key to delivering a reliable product. I will conduct detailed static and dynamic load analyses, focusing on the 3 m × 3 m configuration while ensuring that every calculation is grounded in recognized codes. The report will clearly document all assumptions, safety factors, and results, pinpointing any potential joint failures or deformation risks. I’ve successfully completed similar projects, focusing on aluminum structures from design to verification, providing clear and concise reports along the way. Let's explore how I can help you achieve peace of mind with this project. Regards, Soné Joubert
$400 USD in 7 days
0.0
0.0

Riyadh, Saudi Arabia
Member since Jun 23, 2022
$250-750 USD
$30-250 USD
$375-750 CAD
$750-1500 USD
$25-250 USD / hour
$8-15 USD / hour
$15-25 USD / hour
₹750-1250 INR / hour
$250-750 USD
$250-750 USD
min ₹2500 INR / hour
£750-1500 GBP
₹600-1500 INR
$250-750 USD
₹1500-12500 INR
$1500-3000 USD
$30-250 USD
$250-750 USD
$30-250 AUD
$250-750 USD
$1000-4000 USD
$250-750 AUD