
Kapalı
İlan edilme:
Teslimde ödenir
I need a complete lighting concept for a series of industrial warehouses and will rely on DIALux evo for all calculations, visualisations, and documentation. The goal is to achieve safe, uniform illumination that meets current industrial lighting standards while keeping energy consumption reasonable. All work is strictly confined to the warehouse areas—no production lines or office zones are included in this brief. You’ll work from the architectural layout (PDF + DWG) and my target lux levels per activity zone. Where possible, choose luminaires available in my region so I can source them without delays. Emergency lighting points and basic glare control (UGR) also have to be factored in. Deliverables • DIALux evo project file (.evo) with all calculation grids and 3-D views • Calculation report (PDF) summarising maintained lux values, uniformity, UGR, and power density • Fixture schedule with exact model numbers, optics, and quantities • One printable plan (PDF + DWG) showing luminaire positions and circuits Acceptance criteria • Average illuminance and uniformity meet or exceed specified targets in every warehouse zone • UGR maintained at or below 22 along main aisles • File opens error-free in the latest DIALux evo version and uses only catalogued luminaires All source files provided remain confidential and may be used solely for this project.
Proje No: 40062154
20 teklifler
Uzaktan proje
Son aktiviteden bu yana geçen zaman 2 ay önce
Bütçenizi ve zaman çerçevenizi belirleyin
Çalışmanız için ödeme alın
Teklifinizin ana hatlarını belirleyin
Kaydolmak ve işlere teklif vermek ücretsizdir
20 freelancer bu proje için ortalama $28.715 USD teklif veriyor

Hello, we have reviewed your project. Together with my team, we can assist you in every way in terms of architecture. From architectural technical drawings to ultra-realistic 3D photos. We have provided remote support to many offices abroad and we continue to work with them, in this sense, we have important references especially from America and Germany. We create contemporary and traditional buildings with a flexible design approach. We have a command of all architectural and engineering programs and have a carefully established team. Do not forget that you will enjoy working with us and we will decide together with you at every moment of your project, please send us a message to get started. Good day.
$35.000 USD 7 gün içinde
7,8
7,8

Hello i am PhD energy engineer having extensive knoof energy efficiency in lighting systems for buildings. I can work on your project if provided complete drawings, i can work on 1. Exact number of fixtures required 2. Complete DIAlux design of the lighting 3. Selection of appropriate lighting schemes and wattage 4. Complete energy consumption results. Parameters to be considered while design will be. 1. Number of fixtures 2. Lighting efficacy 3. Lighting lux calculations 4. Uniformity calculations 5. Utilization factor of lighting (complete design for appropriate lighting positions) 6. Energy consumption patterns All deliverables shall be provided as mentioned in the proposal. Dr. Fawad Azeem Certified Energy Manager.
$20.000 USD 7 gün içinde
5,4
5,4

Hello, I can develop the complete warehouse lighting concept using DIALux evo, covering calculations, visualisation, and documentation to meet current industrial lighting standards. The work will focus on achieving uniform, glare-controlled illumination with efficient energy use, based strictly on your warehouse layouts and target lux levels. All designs will follow relevant standards (EN 12464-1 / local equivalents) and use regionally available luminaires. Following are the deliverables: • Complete lighting layout showing fixture positions and circuits • Load calculations covering maintained lux, uniformity, UGR, and power density • Fixture schedules • Bill of quantity I wanted to ask: • Can you please share architectural layout? • Can you confirm the target lux levels for each warehouse activity zone? I have 7+ years of experience in projects like: • Industrial warehouse lighting design using DIALux evo • Energy-efficient luminaire selection and layout optimisation Thank you for considering my proposal. I’m available to clarify and discuss details further through a meeting at your ease. Best Regards, Abubakar
$30.000 USD 7 gün içinde
5,1
5,1

Hi Smail E., My name is El Shaer, and I specialize in transforming ideas into striking, photorealistic spaces with 15 years of experience behind me. I’ve already completed high-end work in Morocco, and the results are available in my portfolio. Clients choose me when they want designs that don’t just look good—they feel real. My 3D Rendering, SketchUp modelling, and 3ds Max visualization workflows bring a level of clarity and emotion that helps you see your project before it’s ever built. Take a moment to view my portfolio. Your vision deserves this level of quality. El Shaer
$20.000 USD 3 gün içinde
5,0
5,0

Greetings, I can develop a comprehensive lighting concept for your industrial warehouses using DIALux evo, ensuring uniform, safe, and energy-efficient illumination that meets current industrial standards. I will work from your architectural layouts and target lux levels, selecting catalogued luminaires available locally to streamline sourcing. The design will incorporate emergency lighting points, basic glare control (UGR ≤ 22), and clearly defined circuits. Deliverables include the DIALux evo project file (.evo) with full calculation grids and 3D views, a PDF calculation report summarizing maintained lux, uniformity, UGR, and power density, a detailed fixture schedule with model numbers and quantities, and printable plans in PDF and DWG showing luminaire positions and circuits. All outputs will open error-free in the latest DIALux evo version and comply with your acceptance criteria.
$20.000 USD 4 gün içinde
4,4
4,4

Hi Smail, I'm excited about the opportunity to design a comprehensive lighting concept for your industrial warehouses. With my experience in DIALux evo, I can ensure safe and uniform illumination that meets industrial standards while optimizing energy consumption. I will utilize the architectural layouts and your target lux levels to carefully select locally available luminaires, factoring in emergency lighting and glare control. My deliverables will include a complete DIALux evo project file, a detailed calculation report, a fixture schedule, and printable plan views. I aim for all acceptance criteria to be met or exceeded, ensuring a smooth implementation for your project.
$20.000 USD 1 gün içinde
3,9
3,9

Hi, I have previously designed lighting systems for large industrial spaces, using DIALux evo to ensure uniform illumination, achieve target lux levels, and meet glare control requirements (UGR). In a recent project, I created a lighting plan for a distribution center, ensuring the layout met energy efficiency goals while maintaining proper lighting levels across all zones, and I provided detailed reports and fixture schedules. I'd love to share my experiences with you. Best regards, Tab
$30.000 USD 15 gün içinde
2,1
2,1

Greetings! I’m a top-rated freelancer with 15+ years of experience and a portfolio of 700+ satisfied clients. I specialize in delivering high-quality, professional Industrial Warehouse Lighting Designing services tailored to your unique needs. Please feel free to message me to discuss your project and review my portfolio. I’d love to help bring your ideas to life! Looking forward to collaborating with you! Best regards, Revival
$35.000 USD 7 gün içinde
1,5
1,5

Casablanca, Morocco
Ara 13, 2025 tarihinden bu yana üye
$30-250 USD
₹600-1500 INR
$10-30 USD
$25-50 USD / saat
$30-250 USD
₹600-1500 INR
$250 USD
₹600-1500 INR
$250-750 AUD
$15-25 USD / saat
₹12500-37500 INR
$30-250 USD
$30-250 SGD
$40-50 USD
₹7990 INR
$30-250 USD
€250-750 EUR
₹150000-250000 INR
₹1500-12500 INR
£20-250 GBP