Closed
Posted
Paid on delivery
I need an engineer to certify the size of the LVL a single leaf brick load-bearing wall that is 3.3 meters wide in my existing house.
Project ID: 40637104
16 proposals
Remote project
Active 5 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
16 freelancers are bidding on average $393 AUD for this job

I read your project details. I'm very much interested to do this project. I'm already experience in it. You can check my previous works at my portfolio section. Please message me for further discussion. I'll provide some of my previous work sample. I'll deliver required Design file according relevant code and detailed drawing file. You will get complete structural solution of following civil structures: 1. RCC Structures (Residential, Commercial, Industrial) 2. Steel Structures (Shed, Multistoried Mezzanine, Silo etc.) 3. Tower (Transmission, Telecommunication) 4. Poles (Steel, SPC) 5. Bridges (Steel, RCC, Composite) 6. Composite Structures (Residential, Commercial, Industrial) 7. Foundation (Single, Combined, Mat, Pile, SPC, Screw etc.) We work with the following Analysis, Drawing and Modeling software: 1. Staad Pro. 2. Etabs 3. MS Tower 4. Auto CAD 5. RAM Connection 6. SketchUp 7. Tekla 8. Revit 9. Robot 10. Advance Steel 11. ASDIP Foundation 12. SAP 13. Tekla Tedds 14. GRASP 15. Staad Foundation 16. CSI Detailing 17. MIDAS Civil
$250 AUD in 1 day
6.0
6.0

Hello, I’m Mohand, a Professional Structural Engineer experienced in residential structural assessments and LVL beam design. Scope of Work: Review the existing house structure, 3.3m load-bearing brick wall opening, and available drawings/site information. Calculate and verify the required LVL size based on the supported loads, span, bearing, and applicable building codes. Provide structural calculations and an engineering certification/report confirming the proposed LVL size, subject to site and jurisdiction requirements. I’ll focus on safe load transfer, adequate bearing, deflection, and practical installation requirements. Please send the existing plans, photos, and any available information about the floor/roof structure above the wall so I can review the requirements. Best Regards, Mohand
$500 AUD in 7 days
5.3
5.3

Hello, I have experience reviewing existing residential load-bearing walls, sizing LVL beams, and preparing structural notes for wall removal or opening support. I’m interested in this project because the 3.3m single-leaf brick wall needs a safe beam recommendation with clear certification for the existing house conditions. I will review the wall location, span, roof/floor loads, bearing points, photos, and any available drawings before confirming the correct LVL size and support requirements. I will also check padstones/posts, load path, deflection, and installation notes so the beam can be safely used for construction or approval. I am not personally licensed to certify structural work in your jurisdiction, but I can provide certified results through a licensed structural engineer collaborator with active local licensure. Thanks for reading my proposal. Edwin
$500 AUD in 7 days
4.8
4.8

Hello, As a Licensed Structural Engineer with over 12 years of experience in residential structural design, load-bearing wall alterations, and beam sizing, I'd be pleased to review the existing conditions and determine the appropriate LVL size and specification. I'll assess the loads supported above the wall, verify the required beam capacity and bearing conditions, and provide the structural documentation needed for your project and approval process. I've completed many similar residential projects involving wall removals, new structural openings, LVL beams, and existing masonry construction. I'd be happy to discuss the existing structure and help ensure the proposed opening is safe and properly engineered.
$250 AUD in 2 days
2.4
2.4

Dear Client, I reviewed your project requirements and I am interested in working with you. I have extensive experience delivering Structural Engineering and Engineering. I focus on understanding the requirements clearly, providing a practical solution, and delivering accurate, well-documented work on schedule. I can review your existing materials, identify the best technical approach, and manage the project from planning through final delivery. You will receive clear communication, regular progress updates, and full support throughout the project. I am available to begin immediately and would be glad to discuss the scope, timeline, and budget. Best regards, Elijah M.
$700 AUD in 6 days
0.0
0.0

Hello! I understand you need a structural engineer to verify and certify the required LVL size for a 3.3 m-wide opening in an existing single-leaf brick load-bearing wall. I have experience with load-path assessments, LVL beam sizing, existing masonry structures, bearing and connection checks, and preparation of engineering documentation suitable for building approval. I will assess the loads carried by the wall, determine the required LVL size and bearing conditions, check deflection and stability, and provide the appropriate calculations and certification based on the site and existing structure. I would be glad to communicate further to review the opening, roof/floor loads, and available site information.
$250 AUD in 3 days
0.0
0.0

I will check the LVL for bending, shear, deflection and support/bearing requirements, and assess the adequacy of the supporting brickwork and bearing locations where sufficient information is available. I will also consider the existing building conditions and identify any information or site verification required to complete the assessment reliably.
$300 AUD in 2 days
0.0
0.0

Hello, I am Karthi and I am a registered member of Engineers Australia (MIEAust.). I graduated in Structural engineering at UNSW, Sydney. I have more than 9 years of experience in the Structural Engineering field at Australia. Currently working for a structural consultant in Sydney on a work from home basis from India. I saw your ad description and attached drawing and I am interested in converting the load bearing wall to framed structure. I have previous experiences designing this complying to Australian Standards. Kindly initiate chat to discuss more. Thanks.
$250 AUD in 2 days
0.0
0.0

Australia
Member since Oct 13, 2022
$250-750 AUD
$250-750 USD
€30-250 EUR
$750-1500 USD
₹12500-37500 INR
₹1500-12500 INR
$750-1500 USD
$250-750 USD
min $50 USD / hour
$750-1500 USD
$250-750 USD
$1500-3000 USD
$750-1500 USD
$10-15 USD
$10-30 USD
$15-25 USD / hour
$750-1500 USD
$250-750 USD
$250-750 USD
$1500-3000 AUD
$30-250 AUD