
Closed
Posted
Paid on delivery
I have nine storage tanks currently certified for 21.5 PPG drilling mud. I now need an engineering review to confirm whether they can safely handle a 22 PPG mud weight. What I will supply • The latest GA drawings with full dimensions for all nine tanks. • Notes on current operating practices and fluid levels. Scope of your evaluation The main objective is to verify structural integrity at the higher density. No formal ASME or API stamp is required at this stage, but please apply recognised best-practice methods and cite the codes or factors of safety you use. Key tasks 1. Analyse wall, roof and support stresses under the increased specific gravity. 2. Identify any weak points or failure modes related to welds, nozzles, baffles or supports. 3. Highlight additional data that might refine the analysis (e.g., material specs or pressure ratings) so I can source it if necessary. 4. Provide clear recommendations, including any modifications or monitoring that would be needed for safe operation at 22 PPG. Deliverables • A concise engineering report with calculations, assumptions and conclusions. • Marked-up drawings or sketches pinpointing critical areas. • A short summary slide or table I can share with operations leadership. Acceptance criteria The report must demonstrate load paths, show calculated safety factors versus allowable limits, and state a clear pass/fail verdict for 22 PPG. Where modifications are advised, quantify the required capacity increase. Please let me know your preferred analysis tool (e.g., FEA package, spreadsheet method) and the estimated turnaround time once drawings are in hand.
Project ID: 40759303
16 proposals
Remote project
Active 1 min ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
16 freelancers are bidding on average $196 USD for this job

Hello, I am Dr. Rajesh Rolen, PhD in Computer Science & Engineering, with experience of over 20+ years in Risk Assessment As a preferred freelancer in the top 1%, I have done 400+ projects here on freelancer.com, I have 4.9 ratings out of 5 on average, which showcases my quality of work and timely delivery. Key Highlights: - Free Hosting Support on the Cloud or any desired platform. - Free 3 months of post-delivery support to ensure that our client doesn’t face any challenges after the launch of the project. - Free Dedicated tester on projects to ensure quality delivery, so clients don’t need to act as a tester. - 10+ Years experience UI/UX team to ensure intuitive UI. Portfolio: https://www.freelancer.com/u/Microlent Please open the chat and send me a message, so we can have a more detailed discussion about the project to give you the project timeline and cost. Thank you for considering my services. I look forward to engaging in a productive conversation and understanding how I can be of assistance in bringing your project to life. Regards Rajesh Rolen
$140 USD in 10 days
6.7
6.7

Hi, I can provide an engineering assessment of all nine mud tanks for a fixed fee of $750, with delivery in 5 days from complete inputs. At the same fill height, increasing mud weight from 21.5 to 22 PPG raises hydrostatic loading by 2.33%. The assessment must establish whether the walls, stiffeners, partitions, welds and supports retain adequate capacity. I will use engineering calculations supported by targeted ANSYS Mechanical analysis, trace the load paths and check the agreed operating and compartment-fill cases. The review will cover the nine supplied tank configurations, including relevant roof/equipment loads and nozzle connections. You will receive a calculation report with assumptions, applicable criteria, safety factors and conclusions; marked-up drawings identifying critical areas; a one-page decision table for operations; and quantified strengthening recommendations where required. One consolidated review round is included. Before analysis, we will confirm the governing drawings, maximum fill levels, material grades, plate/stiffener and weld details, supports, and available thickness/inspection records. Conclusions will identify any evidence gaps; missing data will not be treated as a safe pass. No formal code stamp is included. The five-day schedule starts after award, milestone funding and receipt of the required inputs. I would welcome the opportunity to help your team reach a clear, documented decision. Best regards, Gökay
$750 USD in 5 days
6.7
6.7

Hello, i am ready exited to work you as i read your job description I am also an expert in making 2d,3d modelling and animating characters 2dautocad drawing ,elevation, solid work, Revit ,FBX ,Unity, Render also interior and exterior design. I have experience in field of more than 10+ years. I can Create Intro and Explainer Videos. for products and companies. Kindly check My Portfolio as well. Hope for your very soon reply. Thank you
$120 USD in 2 days
6.3
6.3

Hello. I am using ANSYS for FEA evaluation. Your tank alwayst stay on the ground ? or theye are transfering or lifting. I can test all the tank all live situation which can occur. I can send some of my FEA Reports related to tank evaluation. Feel free to contact me.
$240 USD in 7 days
6.1
6.1

Hi, I can assist with reviewing your nine storage tanks for the increased 22 PPG mud density. I will focus on wall, roof, weld, nozzle, and support stresses, identifying potential weak points and required safety improvements. I can prepare a technical report with calculations, assumptions, marked-up drawings, safety factors, and clear recommendations. I’d be happy to review the drawings and discuss the analysis scope and turnaround time. Best regards
$140 USD in 7 days
4.6
4.6

Hello I will evaluate your request using the Tank software, analyze the effect of density changes on tank pressure, and present the results to you. I look forward to the opportunity to collaborate with you.
$250 USD in 25 days
4.7
4.7

Hello, I reviewed the requirements, and the core challenge is determining whether all nine tanks can withstand the increased hydrostatic loads at 22 PPG without exceeding applicable structural limits. I would focus on reviewing the GA drawings, operating conditions, material data, wall and roof stresses, support loads, welds, nozzles, and potential failure modes. The assessment should document assumptions, applicable standards, and calculation methods, with clear findings and marked-up drawings for review by a qualified tank engineer. Also a quick question, could you please clarify the tank construction type, material specifications, and the code or standard used for their original 21.5 PPG certification? Best Regards, Muskan.
$140 USD in 1 day
3.0
3.0

Are you looking for an experienced mechanical/structural CAD and engineering analysis professional to support the structural review of your nine existing drilling-mud storage tanks for the proposed increase from 21.5 PPG to 22 PPG? I can help organize the engineering assessment around your GA drawings, operating conditions, material data, and existing design basis, with particular attention to wall stresses, roof loading, supports, welds, nozzles, and baffles. I have 8 years of experience in mechanical CAD, structural documentation, engineering calculations, and industrial equipment design support. My proposed approach is to establish the governing loads Deliverables Review of GA drawings and operating conditions for all nine tanks Comparison of loading at 21.5 PPG and 22 PPG Assessment of wall, roof, support, nozzle, baffle, and weld-related concerns Documented assumptions, calculation methods, applicable standards, and safety factors Identification of missing material properties, thicknesses, weld details, and pressure ratings Marked-up drawings highlighting critical areas Questions Are the tanks atmospheric, vented tanks, or designed for any internal pressure? Can you provie the tank material grades, plate thicknesses, weld details, support arrangements, and original design codes? Are there any corrosion measurements, inspection reports, maximum fill levels, or operating-pressure/vacuum limits available? Best regards
$70 USD in 3 days
2.9
2.9

Hi, I can assist with reviewing the tank drawings and preparing a structured engineering assessment of the proposed increase from 21.5 to 22 PPG. I can help evaluate wall, roof, support, weld, nozzle, and baffle details, document assumptions and potential failure points, and prepare calculation summaries, marked-up drawings, and a concise report for your operations team. I have experience with structural drafting, steel framing, and engineering documentation. I’m not a licensed structural engineer, so the final safety verdict and any operational approval should be verified by a qualified engineer with the appropriate tank-design experience. Please share the GA drawings, material specifications, tank dimensions, operating fluid levels, and available design records. I can then review the scope and suggest a suitable analysis workflow and realistic turnaround.
$150 USD in 2 days
3.0
3.0

Hello, I am a Mechanical Engineer with over 15 years of experience in industrial manufacturing, storage tanks, pressure equipment, and fabrication engineering. My proposed approach uses spreadsheet-based engineering calculations supported by hand calculations and applicable engineering standards. Scope of work: • Review drawings, materials, dimensions, and operating conditions for all nine tanks. • Evaluate load paths and relevant stresses at 22 PPG. • Check allowable limits and calculate utilization ratios and safety factors. • Identify critical areas involving tank walls, welds, nozzles, stiffeners, baffles, and supports, as applicable. • Provide a documented PASS/FAIL assessment for each tank, subject to data completeness and defined acceptance criteria. • Quantify required capacity increases and recommend reinforcement where justified. • Deliver a concise engineering report, marked-up drawings, and a management summary table. Bid: $225 USD | Delivery: 7 days after receiving and reviewing complete drawings and relevant technical data. Missing information, assessment limitations, and any need for further inspection will be documented. This assessment is not a formal inspection certificate or operating approval. I look forward to reviewing your drawings and confirming the scope before starting. Best regards
$225 USD in 7 days
2.5
2.5

As a highly skilled Risk Assessor, I have invaluable experience in evaluating complex systems and infrastructure and providing actionable solutions to ensure optimal safety and functionality. While my profile may not immediately appear aligned with your specific tank integrity check project, my expertise in risk management, computer security, and encryption equips me perfectly for this role. Demonstrably proficient in analysis tools such as ADINA or COMSOL Multiphysics that are regularly used in Finite Element Analysis (FEA), my technological fluency will help me quickly adapt to your preferred analysis software. In terms of the task at hand, my ability to identify weak points or potential failure modes would be especially beneficial. Having performed numerous systems analyses in high-pressure environments, I understand that even seemingly trivial issues like faulty welds or inadequate support can lead to catastrophic failures. With your GA drawings and operating notes, I will precisely analyze the structures’ wall, roof, and support stresses under the heightened density. Additionally, I will not merely provide a thorough engineering report but also mark-up critical areas on the tank design so you can visualize precisely which sections require attention.
$250 USD in 1 day
0.0
0.0

To confirm these nine tanks can safely handle 22 PPG, I will evaluate the shell integrity against API 650 and the structural supports against AISC 360 to establish clear safety factors. My approach uses Mathcad for global load paths and primary hoop stresses, paired with FEA (ANSYS) to analyze localized stress concentrations around nozzle junctions, internal baffles, and skid tie-downs. I will start by reviewing your GA drawings and operating notes. If we need extra data to avoid overly conservative assumptions—like base metal yield strengths, weld joint efficiencies, or corrosion allowances—I will let you know right away. You will receive a concise engineering report showing the calculations, load paths, and a definitive pass/fail verdict. If modifications are needed to safely hit 22 PPG, I will quantify the exact capacity shortfall and provide marked-up sketches for structural additions, like external stiffening rings. I will also include the summary slide for your operations leadership.
$140 USD in 7 days
0.0
0.0

Drawing from our extensive experience in Mechanical Engineering and Project Management, we at MOCUB can guarantee an exemplary service that surpasses your expectations. Safety is paramount in any project we undertake, and we are perfectly placed to address your need for tank integrity checks to handle 22 PPG mud weight. We have vast knowledge in analysing the structural integrity of components subjected to different loads and conditions. Using recognised best-practice methods aligned with relevant codes, our approach ensures comprehensive evaluations. We will apply a multi-faceted approach by analysing wall, roof and support stresses as well as identifying any failure modes related to welds, nozzles, baffles or supports. By critically assessing all aspects of these mud tanks, we will generate a concise engineering report with clear recommendations tailored specifically to your operations.
$140 USD in 7 days
4.0
4.0

Kuwait City, Kuwait
Member since Oct 4, 2026
$30-250 USD
€8-30 EUR
$5000-10000 USD
£20-250 GBP
$25-50 USD / hour
$250-750 USD
$25-50 USD / hour
€250-750 EUR
₹1500-12500 INR
$30-250 USD
$750-1500 CAD
€250-750 EUR
₹12500-37500 INR
₹750-1250 INR / hour
$1500-3000 CAD
$750-1500 USD
₹750-1250 INR / hour
₹6000-10000 INR
₹12500-37500 INR
$250-750 USD
$15-25 USD / hour